Difference between revisions of "Vent"

From RimWorld Wiki
Jump to navigation Jump to search
m
 
(18 intermediate revisions by 5 users not shown)
Line 1: Line 1:
<!--Top Nav Box-->
+
{{infobox main|temperature
{| align=center
 
| {{Architect_Nav}}
 
|}
 
----
 
<!-- End of Nav -->
 
 
 
{{infobox main|temperature||
 
 
| name = Vent
 
| name = Vent
 
| image = Vent.png
 
| image = Vent.png
| type = Temperature
+
| type = Building
| placeable = yes
+
| type2 = Temperature
 +
| placeable = True
 
| size = 1 ˣ 1
 
| size = 1 ˣ 1
 
| description = A simple vent for equalizing the temperature between two rooms without allowing people to walk between them.
 
| description = A simple vent for equalizing the temperature between two rooms without allowing people to walk between them.
 
| hp = 100
 
| hp = 100
 +
| cover = 1.0
 +
| terrain affordance = Medium
 
| flammability = 1
 
| flammability = 1
| resources to make = {{icon|steel|30}}
+
| research = Complex furniture
| deconstruct yield = {{icon|steel|23}}
+
| work to make = 400
 +
| resource 1 = steel
 +
| resource 1 amount = 30
 
}}
 
}}
{{Info|A '''vent''' conducts some of the [[temperature]] from one room to another room. It structurally acts like a wall to separate rooms and it supports a roof. Placement of a vent requires open space on its two sides (no solid structures such as walls). The blueprint can be laid atop an existing wall; the wall is replaced upon construction. The placement of multiple vents along a wall increases the temperate transference. Requires the Complex Furniture research to build.}}
+
{{Info|A '''vent''' allows transfer of [[temperature]] and [[gas]]es from one room to another.}}
 +
 
 +
== Acquisition ==
 +
Vents can be constructed once the [[Research#{{P|Required Research}}|{{P|Required Research}}]] research project has been completed. Each requires {{Required Resources}}, {{Ticks|{{P|Work To Make}}}} of work, and a [[{{P|Skill 1}}]] skill of {{P|Skill 1 Level}}. Placement of a vent requires pathable space on either side - furniture such as [[stool]]s will not impede function, but a [[wall]] would.
 +
 
 +
The blueprint can be laid atop an existing wall; the wall is replaced upon construction.  
 +
 
 +
== Summary ==
 +
{{Stub|section=1|reason=1) Gas spread mechanics 2) Hard numbers for temperature transfer in both open and closed states}}
 +
Vents act structurally like a wall, preventing movement, enclosing a [[room]], and supporting a [[roof]]. They have two states - open and closed. In the open state, they allow the transfer of [[temperature]] and [[gas]] from one room to another at their full rate.{{Check Tag|What rate?}} Even when open, vents are not 100% efficient at equalizing temperatures between rooms.{{Check Tag|Quantify}} When closed, the transfer of temperature is reduced{{Check Tag|What rate?}}{{Check Tag|Same as normal wall?}} and the transfer of gas is ceased entirely. The vent can be designated for opening or closing by the player, which will then be actioned by a pawn assigned to [[Work#Basic|Basic]] work.
 +
 
 +
As with walls, the transfer rate is directly proportional to the number of tiles however temperature equalization itself is non-linear. Thus, more vents will decrease the time to reach stability.
 +
 
 +
A vent cannot be uninstalled, only deconstructed, at the usual loss of half the material.
 +
 
 +
== Analysis ==
 +
{{Stub|section=1|reason=Needs thermal transfer rate analysis vs walls, double walls, closed doors and open doors}}
 +
{{Image wanted|section=1|reason=Temperature overlay picture of 2 structures with a hallway and attached bedrooms. 1 with vents between hallway and room and heater in hallway, 1 with vents between rooms and heater in a bedroom}}
  
Since Alpha 17 they can be opened and closed with a simple flick action.
+
General tip: As efficiency is lost for every vent, minimising the number of vents between source and destination is ideal. Heat or cool one central room and vent to the surrounding rooms, rather than attempting to daisy chain many vents.
  
 +
== Version history ==
 +
* [[Version/0.17.1546|0.17.1546]] - Vents can now be opened and closed with a simple flick action.
 +
* [[Version/1.4.3555|1.4.3555]] - Gases can now travel through vents.
 
{{nav|temperature}}
 
{{nav|temperature}}
 
[[Category:Temperature]]
 
[[Category:Temperature]]

Latest revision as of 23:25, 20 September 2023

Vent

Vent

A simple vent for equalizing the temperature between two rooms without allowing people to walk between them.

Base Stats

Type
BuildingTemperature
Market Value
58 Silver [Note]
HP
100
Flammability
100%

Building

Size
1 × 1
Placeable
True
Cover Effectiveness
75%
Terrain Affordance
Medium

Creation

Required Research
Complex furniture
Work To Make
400 ticks (6.67 secs)
Resources to make
Steel 30
Deconstruct yield
Steel 15
Destroy yield
Steel 7 - 8

A vent allows transfer of temperature and gases from one room to another.

Acquisition[edit]

Vents can be constructed once the Complex furniture research project has been completed. Each requires Steel 30 Steel, 400 ticks (6.67 secs) of work, and a [[]] skill of . Placement of a vent requires pathable space on either side - furniture such as stools will not impede function, but a wall would.

The blueprint can be laid atop an existing wall; the wall is replaced upon construction.

Summary[edit]

Vents act structurally like a wall, preventing movement, enclosing a room, and supporting a roof. They have two states - open and closed. In the open state, they allow the transfer of temperature and gas from one room to another at their full rate.[What rate?] Even when open, vents are not 100% efficient at equalizing temperatures between rooms.[Quantify] When closed, the transfer of temperature is reduced[What rate?][Same as normal wall?] and the transfer of gas is ceased entirely. The vent can be designated for opening or closing by the player, which will then be actioned by a pawn assigned to Basic work.

As with walls, the transfer rate is directly proportional to the number of tiles however temperature equalization itself is non-linear. Thus, more vents will decrease the time to reach stability.

A vent cannot be uninstalled, only deconstructed, at the usual loss of half the material.

Analysis[edit]

General tip: As efficiency is lost for every vent, minimising the number of vents between source and destination is ideal. Heat or cool one central room and vent to the surrounding rooms, rather than attempting to daisy chain many vents.

Version history[edit]

  • 0.17.1546 - Vents can now be opened and closed with a simple flick action.
  • 1.4.3555 - Gases can now travel through vents.